6.5 Recommended examination lot acceptance/rejection criteria. If, as a result of the examination of the
packaged lot, the number of defective or under-filled containers exceeds the reject limit number of table III, the lot
represented by the sample should be rejected as specified (see 6.2).
TABLE III. Lot acceptance/rejection criteria.
Lot Size
Sample Size
Reject Limit
1-13
All
Any
14-150
13
1
151-250
32
2
251-500
50
3
501-1,200
80
4
1,201-3,200
125
6
3,201-10,000
200
11
10,001-35,000
315
15
35,001 and over
500
22
NOTES:
1.
All defective items should be replaced with acceptable items
prior to lot acceptance.
2.
Inspect sample size until reject criteria are reached.
3.
Rejected lots may be screened and resubmitted for inspection
and retest.
6.6 Subject term (key word) listing.
Boiler
Diesel engine
Diesel fuel
Fischer-Tropsch Hydroprocessed Synthetic Paraffinic Diesel (FT-SPD)
Gas turbine engine
Hydroprocessed Esters and Fatty Acids (HEFA)
Hydroprocessed/Hydrotreated Renewable Diesel (HRD)
Lubricity
Marine diesel
Marine gas oil
Metal deactivator
Paraffinic Middle Distillate (PMD)
Refined hydrocarbon distillate fuel
Synthesized Paraffinic Diesel (SPD)