MIL-DTL-16884N
APPENDIX A
b.
Fuel system pressure: 3.45 MPa (500 psig)
c.
Fuel flow rate: 3.0 mL/minute
d.
Test duration: 150 minutes
A.4.5.2 ASTM D3241 procedure.
a. The differential pressure in mm Hg at 150 minutes or time to differential pressure of 25 mm Hg,
whichever comes first, shall be recorded.
b.
The heater tube deposit code rating shall be recorded at the end of the test.