MIL-DTL-46162E
TABLE II. Physical and chemical requirements and test methods for
type II referee fuel - Continued.
1/ To be reported if requested by contract or work order- not limited.
2/ A condenser temperature of 0 to 4°C (32 to 40°F) shall be used for the distillation by
ASTM D86. Distillation shall be corrected to 760 mm pressure.
3/ ASTM D93 is the referee method. Method IP 170 is also permitted. The min flash
point shall be 40°C by ASTM D56, as it can be 1 to 2°C (1.8 to 3.6°F) lower than
those obtained by other methods.
4/ When the fuel distillation test is performed using ASTM D2887, the average
distillation temperature, for use in ASTM D3338 shall be calculated as follows:
V = (10 % + 50 % + 95 %) / 3
5/ See 4.3.2.1 through 4.3.2.4 for ASTM D3241 test conditions and test limits.
6/ The min water separation index rating for referee JP-8 shall be 85 with all additives
except the corrosion inhibitor/lubricity improver additive and the static dissipator
additive or 70 with all additives except the static dissipator additive.
7/ Unless otherwise specified (see 6.2), the conductivity must be between 150 and
600 pico Siemens (pS)/meter (m)) for F-34 and between 50 and 450 pS/m for F-35.
3.4 Material safety. The contractor shall comply with the material safety requirements of
FED-STD-313 (see 6.4.1).
3.5 Workmanship. At the time of Government acceptance, the finished referee fuel shall be
visually free from undissolved water, sediment, and suspended matter; and shall be clear and
bright when tested in accordance with ASTM D4176, procedure 1, methods A and B (see 4.1.2).
4. VERIFICATION
4.1 Classification of inspection. The inspection requirements specified herein are classified
as quality conformance tests.
4.1.1 Conformance inspection. Conformance inspection shall include those examinations
and tests for all requirements specified in section 3, table I, table II and as defined in the contract.
Quality conformance inspection shall include the test requirements herein.
4.1.2 Container inspection. Perform container inspection in accordance with FED-STD-791,
method 9601 and shall be visually examined for compliance with 3.5.
4.1.2.1 Examination of empty container. Prior to filling, each empty unit container shall be
visually inspected for cleanliness and suitability.
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business