MIL-DTL-46162E
APPENDIX B
g. Forceps: Flat-bladed with unserrated nonpoint tips.
h. Solvent filtering dispenser: Containing a 1.2 micrometers (0.0002 in.) maximum port
size filter in the delivery line.
i. Glass petri dish: Approximately 125 mm (4.9 in.) in diameter with removable cover.
j. Analytical balance: Single or double pan, the precision standard deviation of which
must be 0.07 milligrams (mg) (2.5 oz)) or better.
FIGURE 1. Filtration apparatus.
B.5 Preparation of apparatus and sample containers. All components of the filtration
apparatus (except the vacuum flask), sample containers and their caps must be cleaned as
described in section 10 of ASTM D5452. All metal parts of the filtration apparatus are to be
electrical bonded including the fuel sample container and the metal insert ring, if used.
See ASTM D5452 for other Precautionary Statements.
B.6 Sampling. Obtain a representative one gallon sample as directed in ASTM D5452
section 8, Sampling. When sampling from a flowing stream is not possible, an all level sample
or an average sample, in accordance with ASTM D4057 or ASTM D4177 shall be permitted.
The one-gallon sample container shall be an interior epoxy coated metal can, a brown glass
bottle, or one-gallon sample container shall be an interior epoxy coated metal can, a brown
glass bottle, or a clear glass bottle protected by suitable means from exposure to light.
21